Features:
Quad Output 5V 15V -5V -15V
Full range AC Input
Built-in EMI filter,tiny ripple
Cooling by free air convection
Protection:short circuit,overload,over voltage
100% full load burn-in test
2 years warranty
| Quad Output Power Supply | ||||||
| Series | Wattage(W) | Input(VAC) | Output(VDC) | Cooling method | Size(mm) | Warranty(year) |
| Q-60B | 60 | 85-264 | Ch1:5V5.5A Ch2:12V2A Ch3:-5V0.5A Ch4:-12V0.5A | Air convection | 159*97*38 | 2 |
| Q-60C | Ch1:5V5.5A Ch2:15V1.5A Ch3:-5V0.5A Ch4:-15V0.5A | |||||
| Q-60D | Ch1:5V4A Ch2:12V1A Ch3:24V1A Ch4:-12V0.5A | |||||
| Q-120B | 120 | 85-132/170-264 | Ch1:5V12A Ch2:12V5A Ch3:-5V1A Ch4:-12V1A | 199*110*50 | ||
| Q-120C | Ch1:5V12A Ch2:15V5A Ch3:-5V1A Ch4:-15V0.5A | |||||
| Q-120D | Ch1:5V8A Ch2:12V3A Ch3:24V1A Ch4:-12V0.5A | |||||
| For specific parameters, please refer to the datasheet. Additionally, we provide customization services. If you have any needs, feel free to contact us anytime. |
||||||
Specifications:
| Model | Q-60B | Q-60C | Q-60D | ||||||||||
| Output | Output Number | Ch1 | Ch2 | Ch3 | Ch4 | Ch1 | Ch2 | Ch3 | Ch4 | Ch1 | Ch2 | Ch3 | Ch4 |
| DC voltage | 5V | 12V | -5V | -12V | 5V | 15V | -5V | -15V | 5V | 12V | 24V | -12V | |
| Rated current | 5.5A | 2A | 0.5A | 0.5A | 5.5A | 1.5A | 0.5A | 0.5A | 4A | 1A | 1A | 0.5A | |
| Current range | 0-8A | 0.1-2A | 0-1A | 0-1A | 0.5-6A | 0.1-2A | 0-1A | 0.5-1A | 0.5-6A | 0.1-3A | 0.1-1.5A | 0-1A | |
| Rated power | 60W | 60W | 62W | ||||||||||
| Ripple&noise | 100mVp-p | 120mVp-p | 100mVp-p | 120mVp-p | 100mVp-p | 120mVp-p | 100mVp-p | 120mVp-p | 100mVp-p | 120mVp-p | 100mVp-p | 100mVp-p | |
| Voltage adj.range | Ch1+10,-5% | ||||||||||||
| Voltage tolerance | ±2.0% | ±6.0% | ±5.0% | ±5.0% | ±2.0% | ±4.0% | ±5.0% | ±5.0% | ±2.0% | ±6.0% | ±4.0% | ±5.0% | |
| Line regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±2.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±2.0% | ±0.5% | |
| Load regulation | ±0.5% | ±4.0% | ±1.0% | ±1.0% | ±0.5% | ±4.0% | ±1.0% | ±1.0% | ±0.5% | ±0.5% | ±4.0% | ±1.0% | |
| Set up,rise time | 800ms,20ms/230VAC 1600ms,20ms/115VAC(full load) | ||||||||||||
| Hold up time(Typ.) | 70ms/230VAC 15ms/115VAC(full load) | ||||||||||||
| Input | Voltage range | 85~264VAC or 120~373VDC | |||||||||||
| Frequency | 47 ~ 63Hz | ||||||||||||
| Efficiency | 70% | 72% | 75% | ||||||||||
| AC current | 2A/115VAC 0.8A/230VAC | ||||||||||||
| Inrush current | Cold start: 15A/115VAC 30A/230VAC | ||||||||||||
| Leakage current | <1mA/240VAC | ||||||||||||
| Protection | Overload | Rated output power 105%~150% | |||||||||||
| Protection type : Hiccup mode, recovers automatically after fault condition is removed |
|||||||||||||
| Over voltage | 5V:5.75~6.75 | ||||||||||||
| Protection type : Hiccup mode, recovers automatically after fault condition is removed |
|||||||||||||
| Environment | Working temperature | -10℃~+60℃ | |||||||||||
| Working humidity | 20-90%RH | ||||||||||||
| Storage temp,humidity | -20~+85℃,10%-95%RH | ||||||||||||
| Temp.coefficient | ±0.03%℃(0-50℃)(+5V) | ||||||||||||
| Vibration | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||||||||
| Safety & EMC |
Safety standards | Compliance to:CE and GB4943.1 safety standards | |||||||||||
| Withstand voltage | I/P-O/P:1.5KVAC 1minute I/P-FG:1.5KVAC 1minute O/P-PG:0.5KVAC 1minute | ||||||||||||
| Isolation resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||||||||
| EMC emission | EN61000-3-2:2014/EN61000-3-3:2013 | ||||||||||||
| EMC immunity | EN 55032:2015/EN55035:2017/60950-1 | ||||||||||||
| Others | MTBF | ≥284.8K hrs MIL-HDBK-217F(25℃) | |||||||||||
| Size | L159*W98*H38mm | ||||||||||||
| Packing | 0.45KG | ||||||||||||
| Note | 1. All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25℃ of ambient temperature. 2. Ripple&noise are measured at 20MHz of bandwidth by using a 12 "twisted pair -wire terminated with a 0.1uf and 47uf parallel capacitors. 3. Tolerance:includes set up tolerance,line regulation and load regulation. 4. Derating output is required under low input voltage. Please refer to the derating curve for details. 5. The power supply should be considered as a part of the components in the system. All EMC tests will test the test samples on a metal iron plate with a thickness of 1mm, a length of 360mm * width of 360mm. |
||||||||||||