Model Specification Table
Model |
RSP-500-12 |
RSP-500-15 |
RSP-500-24 |
RSP-500-27 |
RSP-500-48 |
Output Voltage |
12V |
15V |
24V |
27V |
48V |
Rated Current |
41.7A |
33.4A |
21A |
18.6A |
10.5A |
Current Range |
0–41.7A |
0–33.4A |
0–21A |
0–18.6A |
0–10.5A |
Rated Power |
500.4W |
501W |
504W |
502.2W |
504W |
Ripple & Noise |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
Voltage Adj. Range |
10–13.2V |
13.5–18V |
20–26.4V |
26–30V |
41–56V |
Voltage Tolerance |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
Line Regulation |
±0.3% |
±0.3% |
±0.2% |
±0.2% |
±0.2% |
Load Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Input Parameters
Parameter |
Description |
Input Voltage Range |
88–264VAC / 124–370VDC |
Input Frequency |
47–63Hz |
PFC Efficiency |
PF > 0.95 (230VAC), PF > 0.98 (115VAC full load) |
Input Efficiency |
88–90.5% (varies by model) |
Input Current (Typical) |
6A/115VAC, 3A/230VAC |
Surge Current |
20A/115VAC, 40A/230VAC |
Leakage Current |
<2.5mA/240VAC |
Protection Functions
Protection Type |
Trigger Condition |
Response Action |
Overload Protection |
105–130% of rated output power |
Hiccup mode, auto-recovery after fault cleared |
Overvoltage Protection |
Output voltage exceeds threshold (model-dependent) |
Shutdown output, re-power-on to recover |
Overtemperature Protection |
Excessive temperature |
Shutdown output, auto-recovery when cooled down |
Environmental Requirements
Parameter |
Requirement |
Operating Temperature |
-30°C to +70°C (refer to derating curve) |
Operating Humidity |
20–90% RH non-condensing |
Storage Conditions |
-40°C to +85°C, 10–95% RH |
Vibration |
10–500Hz, 2G (XYZ axes, 10 min/cycle × 60 cycles) |
Safety & Certification
Item |
Standard/Requirement |
Safety Standards |
GB4943.1, EN 60950.1 APPROVED |
Withstand Voltage |
I/P-O/P: 2kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC |
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100MΩ @ 500VDC/25°C/70%RH |
EMC Compliance |
EN61000-3-2 (2014), EN61000-3-3 (2013) for emissions |
EN55032 (2015)/EN55035 (2017) for immunity |
|
Additional Information
Parameter |
Description |
MTBF (25°C) |
≥187.7K hours (MIL-HDBK-217F standard) |
Dimensions |
230×127×40.5mm (L×W×H) |
Packaging Weight |
Single unit: 1.3kg; 9 units/box: 12.7kg, Volume: 0.7CUFT |
Function Description
Remote Control (CN100)
Pin No. |
Function |
Description |
RC+ (Pin 4) |
Power Control |
0–0.8VDC or open: Power ON |
4–10VDC: Power OFF (dry contact) |
|
|
RC- (Pin 3) |
Return Path |
Ground connection for remote control signals |
Remote Sensing
Compensates voltage drop up to 0.3V on load wiring, ensuring stable output at the terminal.
Key Differences from Previous Models
Higher Power Density: 500W output with compact size (230×127×40.5mm).
Enhanced Cooling: Fan-based cooling for higher efficiency and reliability.
Extended Warranty: 3-year warranty with 2 replacements per year.
Industrial Focus: Robust design for harsh environments (-40°C to +85°C).