| Availability: | |
|---|---|
| Quantity: | |
RSP-200
SMUN
The RSP-200 Series is a highly reliable, 200W single-output enclosed power supply designed with an active Power Factor Correction (PFC) function. Engineered to meet the strict operational demands of telecom systems, industrial automation equipment, and medical devices, this series delivers stable and efficient power conversion. Featuring a low-profile 30mm design, it is an excellent choice for installations where space is limited, such as 1U rackmount applications. The series provides a versatile range of output voltages from 12V to 48V, notably including a specialized 27.3V model that is frequently required for specific telecommunication and DC backup systems. By integrating advanced circuitry, the RSP-200 series helps procurement professionals and engineers reduce energy consumption while ensuring long-term operational stability in critical project environments.
The following table outlines the detailed electrical specifications for each voltage model. Selecting the correct output voltage and rated current is crucial for ensuring compatibility and optimal performance with your specific equipment.
| Model | RSP-200-12 | RSP-200-24 | RSP-200-27.3 | RSP-200-36 | RSP-200-48 |
|---|---|---|---|---|---|
| Output Voltage | 12V | 24V | 27.3V | 36V | 48V |
| Rated Current | 16.7A | 8.5A | 7.3A | 5.5A | 4.2A |
| Current Range | 0–16.7A | 0–8.5A | 0–7.3A | 0–5.2A | 0–4.2A |
| Rated Power | 200W | 204W | 200W | 200W | 201.6W |
| Ripple Noise | 150mVp-p | 150mVp-p | 150mVp-p | 220mVp-p | 240mVp-p |
| Voltage Adj. Range | 10–13.2V | 20–26.4V | 23.5–29.5V | 32.4–39.6V | 41–56V |
| Voltage Tolerance | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
Designed for global applicability, the power supply supports a universal AC input range. The built-in active PFC function significantly improves energy efficiency and reduces the burden on the AC power grid, lowering overall operational costs.
| Parameter | Description |
|---|---|
| Input Voltage Range | 88–264VAC or 124–370VDC |
| Input Frequency | 47–63Hz |
| PFC Efficiency | PF > 0.95 (230VAC) / PF > 0.98 (115VAC full load) |
| Input Efficiency | 88–90% (varies by model) |
| Input Current (Typical) | 4A/115VAC, 2A/230VAC |
| Surge Current | 20A/115VAC, 40A/230VAC |
| Leakage Current | <1.5mA/240VAC |
To minimize downtime and protect valuable connected devices, this series incorporates robust self-recovery protection mechanisms against common electrical faults, effectively lowering project maintenance risks.
| Protection Type | Trigger Condition | Response Action |
|---|---|---|
| Overload Protection | 115–135% of rated output power | Hiccup mode, auto-recovery after fault cleared |
| Overvoltage Protection | Output voltage exceeds threshold (model-dependent) | Output shutdown, auto-recovery after fault cleared |
| Overtemperature Protection | Excessive temperature | Output shutdown, auto-recovery when cooled down |
The robust construction allows the power supply to operate efficiently in harsh environments, making it highly suitable for heavy-duty industrial and outdoor-enclosed applications.
| Parameter | Requirement |
|---|---|
| Operating Temperature | -30°C to +70°C (refer to derating curve) |
| Operating Humidity | 20–90% RH (non-condensing) |
| Storage Conditions | -40°C to +85°C, 10–95% RH |
| Temperature Coefficient | ±0.03%/°C (0–50°C) |
| Vibration | 10–500Hz, 2G (XYZ axes, 10 min/cycle × 60 cycles) |
Compliance with international safety and electromagnetic compatibility (EMC) standards ensures secure operation and helps streamline the certification process for your final product assembly.
| Item | Standard/Requirement |
|---|---|
| Safety Standards | GB 4943.1, EN 60950.1 APPROVED |
| Insulation Resistance | I/P-O/P: 100MΩ @ 500VDC/25°C/70%RH |
| Withstand Voltage | I/P-O/P: 3kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC |
| EMC - Emission: EN55032 (CISPR32) Class B |
Immunity: EN62368-4 series + EN55035 |
Physical dimensions and reliability metrics are provided below to assist engineers with mechanical integration, space planning, and lifecycle management.
| Parameter | Description |
|---|---|
| MTBF (25°C) | ≥206.5K hours (MIL-HDBK-217F standard) |
| Dimensions | 215×115×30mm (L×W×H) |
| Packaging Weight | Single unit: 0.72kg; 30 units/box: 22.5kg, Volume: 0.78 cubic feet |
Please review the following testing conditions and operational guidelines to ensure accurate performance evaluation and safe deployment within your systems.
All unspecified parameters are measured at 230VAC input, full load, 25°C unless noted.
Ripple noise measurements use a bandwidth of 20MHz with 12-inch twisted-pair wires and parallel 0.1μF + 47μF capacitors.
Low-input voltage operation requires derating (refer to derating curves).
EMC testing uses a 1mm-thick steel plate (360×360mm).
When selecting between the RSP-200 and RSP-320 series, consider the following primary differences to accurately match your project's power capacity, thermal management, and weight requirements.
Power Rating: 200W vs. 320W.
Output Voltages: Includes 27.3V (common in telecom/dc systems).
Efficiency: Slightly lower (up to 90%) compared to the 320W series.
Cooling: Free air convection vs. forced air cooling in the 320W series.
Package Weight: Lighter (0.72kg vs. 0.9kg for 320W).